Skip to main content
💧 Water Filtration Case Study · Concord, MA

Concord, MA Historic Estate Radon & Arsenic Remediation

Comprehensive whole-house water filtration engineering eliminating 14,200 pCi/L radon and 16.5 ppb arsenic in Concord, MA while preserving historic architectural integrity.

📞 978-453-8200
Groundwater Engineering Data

Before & After Field Ledger

Initial Problem / Metric
14,200 pCi/L water radon & 16.5 ppb natural arsenic
Pre-intervention baseline measurement
Verified Post-Service Result
<150 pCi/L radon (99% reduction) & non-detect arsenic (<0.5 ppb)
Certified pump flow / lab water analysis
Depth & Strata
510 ft deep bedrock well
Assabet Quartz Diorite & Nashoba Terrane Gneiss
Location & Jurisdiction
Concord, MA
Middlesex County · Licensed MA Driller
The Groundwater Challenge

Symptoms & Site Diagnostics

A comprehensive water potability test on a historic Concord residential property revealed dangerous levels of naturally occurring waterborne radon gas (14,200 pCi/L vs. MassDEP 10,000 pCi/L guidance) and arsenic (16.5 ppb vs. the 10.0 ppb federal drinking water standard). The homeowner required complete whole-house water purification without altering the exterior historic aesthetic or introducing loud exhaust fans.

Turnkey Technical Solution

Execution & Field Intervention

Ogden Wells designed and installed a multi-barrier Point-of-Entry (POE) filtration suite. First, an Air-Cycle sealed diffuse bubble aeration tower was installed in the basement to agitate and exhaust radon gas safely above the roofline. Second, water was passed through a dual-tank Metsorb titanium dioxide adsorption system that permanently binds dissolved arsenic. Finally, a calcite neutralizing media filter was added to correct natural acidity (pH 6.1 to 7.2), protecting the home's copper plumbing.

Documented Client Results

Verified Performance Highlights

✓Post-installation state-certified laboratory tests confirmed radon reduced to <150 pCi/L (>98.9% removal efficiency).
✓Total dissolved arsenic reduced to non-detect (<0.5 ppb), well below the 10 ppb federal drinking water limit.
✓Completely silent interior operation with zero visible equipment outside the historic structure.
✓Achieved full potability certification approved by the Concord Board of Health.

Equipment Deployed & Regulatory Compliance

Hardware & Tooling Deployed

  • • Air-Cycle 4-stage diffuse bubble aeration radon tower with high-efficiency vent fan
  • • Dual Metsorb titanium-dioxide arsenic adsorption vessels with automatic backwash valves
  • • Enpress calcite neutralizing mineral vessel

Codes & Permitting Standards

  • • MassDEP Private Drinking Water Quality Standards
  • • Concord Health Division potability testing protocol
  • • NSF/ANSI Standard 53 & 58 certified drinking water treatment components

Experiencing Low Yield, Poor Pressure, or Contaminants?

Put over 45 years of licensed New England groundwater experience to work for your property. Ogden Wells delivers proven drilling, hydrofracturing, and pump repair.

📞 978-453-8200
📞 Call Now